F401 CHAUVIN ARNOUX


Виробник: CHAUVIN ARNOUX
Category: Meters and AC Clamp Probes
Description: Meter: multifunction; digital,pincers type; LCD; (10000); 5÷20kHz
Type of meter: multifunction
Resistance measuring range: 0.1...99.99kΩ
Resistance measuring accuracy: ±(1%+5 digit)
Measurement: AC current; active power; AC voltage; apparent power; continuity; DC current; DC voltage; frequency; harmonics; inrush current; phase sequence; reactive power; resistance
Measuring instrument features: automatic power-off; HOLD function; low battery indicator; MIN/MAX function; True InRush function
Conform to the norm: CAT III 1500V; CAT IV 1000V; EN 61010
Power supply: battery LR6 AA 1,5V x4
Dimensions: 92x272x41mm
Standard equipment: case; drop-like K-type temperature probe; test leads; test probes
Test: diodes
Continuity test: acoustic indication
Max. diameter of measured cable: 48mm
Temperature measuring range: -60...1000°C
True effective value measurement: True RMS
Kind of meter: digital; pincers type
AC current measuring range: 250mA...1kA
DC voltage measuring range: 150mV...1.7kV
AC voltage measuring range: 150mV...1.2kV
Frequency measuring range: 5...20kHz
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Display parameters: (10000)
Frequency measuring accuracy: ±(0.4%+1 digit)
AC current measuring accuracy: ±(1% + 3 digit)
DC voltage measuring accuracy: ±(1% + 3 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Kind of display used: LCD
Illumination: yes
кількість в упаковці: 1 шт
товар відсутній

Відгуки про товар
Написати відгук

Технічний опис F401 CHAUVIN ARNOUX

Category: Meters and AC Clamp Probes, Description: Meter: multifunction; digital,pincers type; LCD; (10000); 5÷20kHz, Type of meter: multifunction, Resistance measuring range: 0.1...99.99kΩ, Resistance measuring accuracy: ±(1%+5 digit), Measurement: AC current; active power; AC voltage; apparent power; continuity; DC current; DC voltage; frequency; harmonics; inrush current; phase sequence; reactive power; resistance, Measuring instrument features: automatic power-off; HOLD function; low battery indicator; MIN/MAX function; True InRush function, Conform to the norm: CAT III 1500V; CAT IV 1000V; EN 61010, Power supply: battery LR6 AA 1,5V x4, Dimensions: 92x272x41mm, Standard equipment: case; drop-like K-type temperature probe; test leads; test probes, Test: diodes, Continuity test: acoustic indication, Max. diameter of measured cable: 48mm, Temperature measuring range: -60...1000°C, True effective value measurement: True RMS, Kind of meter: digital; pincers type, AC current measuring range: 250mA...1kA, DC voltage measuring range: 150mV...1.7kV, AC voltage measuring range: 150mV...1.2kV, Frequency measuring range: 5...20kHz, Battery/ rechargeable battery: battery LR6 AA 1,5V x4, Display parameters: (10000), Frequency measuring accuracy: ±(0.4%+1 digit), AC current measuring accuracy: ±(1% + 3 digit), DC voltage measuring accuracy: ±(1% + 3 digit), DC current measuring accuracy: ±(1% + 3 digit), AC voltage measuring accuracy: ±(1% + 3 digit), Kind of display used: LCD, Illumination: yes, кількість в упаковці: 1 шт.

Інші пропозиції F401

Фото Назва Виробник Інформація Доступність
Ціна без ПДВ
F401
+1
F401 Виробник : CHAUVIN ARNOUX Category: Meters and AC Clamp Probes
Description: Meter: multifunction; digital,pincers type; LCD; (10000); 5÷20kHz
Type of meter: multifunction
Resistance measuring range: 0.1...99.99kΩ
Resistance measuring accuracy: ±(1%+5 digit)
Measurement: AC current; active power; AC voltage; apparent power; continuity; DC current; DC voltage; frequency; harmonics; inrush current; phase sequence; reactive power; resistance
Measuring instrument features: automatic power-off; HOLD function; low battery indicator; MIN/MAX function; True InRush function
Conform to the norm: CAT III 1500V; CAT IV 1000V; EN 61010
Power supply: battery LR6 AA 1,5V x4
Dimensions: 92x272x41mm
Standard equipment: case; drop-like K-type temperature probe; test leads; test probes
Test: diodes
Continuity test: acoustic indication
Max. diameter of measured cable: 48mm
Temperature measuring range: -60...1000°C
True effective value measurement: True RMS
Kind of meter: digital; pincers type
AC current measuring range: 250mA...1kA
DC voltage measuring range: 150mV...1.7kV
AC voltage measuring range: 150mV...1.2kV
Frequency measuring range: 5...20kHz
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Display parameters: (10000)
Frequency measuring accuracy: ±(0.4%+1 digit)
AC current measuring accuracy: ±(1% + 3 digit)
DC voltage measuring accuracy: ±(1% + 3 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Kind of display used: LCD
Illumination: yes
кількість в упаковці: 1 шт
товар відсутній
F401
+1
F401 Виробник : CHAUVIN ARNOUX Category: Meters and AC Clamp Probes
Description: Meter: multifunction; digital,pincers type; LCD; (10000); 5÷20kHz
Type of meter: multifunction
Resistance measuring range: 0.1...99.99kΩ
Resistance measuring accuracy: ±(1%+5 digit)
Measurement: AC current; active power; AC voltage; apparent power; continuity; DC current; DC voltage; frequency; harmonics; inrush current; phase sequence; reactive power; resistance
Measuring instrument features: automatic power-off; HOLD function; low battery indicator; MIN/MAX function; True InRush function
Conform to the norm: CAT III 1500V; CAT IV 1000V; EN 61010
Power supply: battery LR6 AA 1,5V x4
Dimensions: 92x272x41mm
Standard equipment: case; drop-like K-type temperature probe; test leads; test probes
Test: diodes
Continuity test: acoustic indication
Max. diameter of measured cable: 48mm
Temperature measuring range: -60...1000°C
True effective value measurement: True RMS
Kind of meter: digital; pincers type
AC current measuring range: 250mA...1kA
DC voltage measuring range: 150mV...1.7kV
AC voltage measuring range: 150mV...1.2kV
Frequency measuring range: 5...20kHz
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Display parameters: (10000)
Frequency measuring accuracy: ±(0.4%+1 digit)
AC current measuring accuracy: ±(1% + 3 digit)
DC voltage measuring accuracy: ±(1% + 3 digit)
DC current measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Kind of display used: LCD
Illumination: yes
товар відсутній
F401
+5
F401 Виробник : CHAUVIN ARNOUX CA-F203_DS.PDF CA-F401-M.PDF Category: Meters and AC Clamp Probes
Description: Meter: multifunction; digital,pincers type; LCD; (10000); 5÷20kHz
Type of meter: multifunction
Resistance measuring range: 0.1...99.99kΩ
Resistance measuring accuracy: ±(1%+5 digit)
Measurement: AC current; AC voltage; continuity; DC voltage; frequency; inrush current; resistance; temperature
Measuring instrument features: automatic power-off; HOLD function; low battery indicator; MIN/MAX function; True InRush function
Conform to the norm: CAT III 1000V; CAT IV 1000V; EN 61010; EN 61243-3:2010
Power supply: battery LR6 AA 1,5V x4
Dimensions: 92x272x41mm
Standard equipment: case; drop-like K-type temperature probe; test leads; test probes
Test: diodes
Continuity test: acoustic indication; 1Ω...999Ω
Max. diameter of measured cable: 48mm
Temperature measuring range: -60...1000°C
True effective value measurement: True RMS
Kind of meter: digital; pincers type
AC current measuring range: 150mA...1kA
DC voltage measuring range: 150mV...1kV
AC voltage measuring range: 150mV...1kV
Frequency measuring range: 5...20kHz
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Display parameters: (10000)
Frequency measuring accuracy: ±(0.4%+1 digit)
AC current measuring accuracy: ±(1% + 3 digit)
DC voltage measuring accuracy: ±(1% + 3 digit)
AC voltage measuring accuracy: ±(1% + 3 digit)
Temperature measurement accuracy: ±(1% + 3 digit)
Kind of display used: LCD
Illumination: yes