Fluke 725
  • Fluke 725
  • Fluke 725

Fluke 725


10031-eng-07-a.pdf 725_____umeng0300.pdf 725_____umger0300.pdf Виробник: FLUKE
Category: Calibrators
Description: Calibrator; pressure,frequency,voltage,current,RTD
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads; set of test leads with alligator clips
Related items: POM-5900A/POM; POM-5912B; POM-6173A
Kind of calibrator: current; frequency; pressure; RTD; thermocouple; voltage
Current source accuracy: ±(0,025% + 1 digit)
Voltage source accuracy: ±(0,02% + 2 digits)
Measurement: DC current; DC voltage; resistance
Resistance measuring range: 10mΩ...400Ω; 1.5kΩ; 3.2kΩ
DC current measuring range: 0...24mA
DC voltage measuring range: 0...100mV; 0...30V
Ω simulation: 15...3200Ω
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Current source: 0...24mA
Voltage source: 0...20V
DC voltage measuring accuracy: ±(0.02% + 2 digit)
DC current measuring accuracy: ±(0.02% + 2 digit)
Resistance measuring accuracy: ±(0.1%+1Ω)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
Illumination: yes
Type of device: calibrator
Dimensions: 200x96x47mm
Protection: short circuit protection SCP
Measuring instrument features: 24V, 22mA loop supplying; automatic and manual step setting; automatic linear sourcing; measures and sources frequency within 1 cycle/min. to 10kHz range; measures and sources signals simultaneously from 2 channels; measures pressure up to 700 bar using any FLK-700Pxx pressure module; operates with 7 types of RTDs: Pt100 (385), Pt200, Pt500, Pt1000 (385), Pt100 (3916), Pt100 (3926), Ni120; operates with thermocouple types: J, K, T, E, R, S, B, L, N, U, XK, BP; settings memory
кількість в упаковці: 1 шт
товар відсутній

Відгуки про товар
Написати відгук

Технічний опис Fluke 725 FLUKE

Category: Calibrators, Description: Calibrator; pressure,frequency,voltage,current,RTD, Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads; set of test leads with alligator clips, Related items: POM-5900A/POM; POM-5912B; POM-6173A, Kind of calibrator: current; frequency; pressure; RTD; thermocouple; voltage, Current source accuracy: ±(0,025% + 1 digit), Voltage source accuracy: ±(0,02% + 2 digits), Measurement: DC current; DC voltage; resistance, Resistance measuring range: 10mΩ...400Ω; 1.5kΩ; 3.2kΩ, DC current measuring range: 0...24mA, DC voltage measuring range: 0...100mV; 0...30V, Ω simulation: 15...3200Ω, Battery/ rechargeable battery: battery LR6 AA 1,5V x4, Current source: 0...24mA, Voltage source: 0...20V, DC voltage measuring accuracy: ±(0.02% + 2 digit), DC current measuring accuracy: ±(0.02% + 2 digit), Resistance measuring accuracy: ±(0.1%+1Ω), Kind of display used: LCD, Power supply: battery LR6 AA 1,5V x4, Illumination: yes, Type of device: calibrator, Dimensions: 200x96x47mm, Protection: short circuit protection SCP, Measuring instrument features: 24V, 22mA loop supplying; automatic and manual step setting; automatic linear sourcing; measures and sources frequency within 1 cycle/min. to 10kHz range; measures and sources signals simultaneously from 2 channels; measures pressure up to 700 bar using any FLK-700Pxx pressure module; operates with 7 types of RTDs: Pt100 (385), Pt200, Pt500, Pt1000 (385), Pt100 (3916), Pt100 (3926), Ni120; operates with thermocouple types: J, K, T, E, R, S, B, L, N, U, XK, BP; settings memory, кількість в упаковці: 1 шт.

Інші пропозиції Fluke 725

Фото Назва Виробник Інформація Доступність
Ціна без ПДВ
Fluke 725
+1
Fluke 725 Виробник : FLUKE 10031-eng-07-a.pdf 725_____umeng0300.pdf 725_____umger0300.pdf Category: Calibrators
Description: Calibrator; pressure,frequency,voltage,current,RTD
Standard equipment: crocodile clips FLK-AC72; FLK-TL75 test leads; set of test leads with alligator clips
Related items: POM-5900A/POM; POM-5912B; POM-6173A
Kind of calibrator: current; frequency; pressure; RTD; thermocouple; voltage
Current source accuracy: ±(0,025% + 1 digit)
Voltage source accuracy: ±(0,02% + 2 digits)
Measurement: DC current; DC voltage; resistance
Resistance measuring range: 10mΩ...400Ω; 1.5kΩ; 3.2kΩ
DC current measuring range: 0...24mA
DC voltage measuring range: 0...100mV; 0...30V
Ω simulation: 15...3200Ω
Battery/ rechargeable battery: battery LR6 AA 1,5V x4
Current source: 0...24mA
Voltage source: 0...20V
DC voltage measuring accuracy: ±(0.02% + 2 digit)
DC current measuring accuracy: ±(0.02% + 2 digit)
Resistance measuring accuracy: ±(0.1%+1Ω)
Kind of display used: LCD
Power supply: battery LR6 AA 1,5V x4
Illumination: yes
Type of device: calibrator
Dimensions: 200x96x47mm
Protection: short circuit protection SCP
Measuring instrument features: 24V, 22mA loop supplying; automatic and manual step setting; automatic linear sourcing; measures and sources frequency within 1 cycle/min. to 10kHz range; measures and sources signals simultaneously from 2 channels; measures pressure up to 700 bar using any FLK-700Pxx pressure module; operates with 7 types of RTDs: Pt100 (385), Pt200, Pt500, Pt1000 (385), Pt100 (3916), Pt100 (3926), Ni120; operates with thermocouple types: J, K, T, E, R, S, B, L, N, U, XK, BP; settings memory